These commands sets Signage settings. For example, “SAVEMODELINFO” can be executed to save model name and software version to a removable device, or “SHOWSIGNAGEID” can be executed to display signage ID on screen. These commands can be seen below with their definitions, parameters and returns.

CommandsDefinitionParametersReturn
GETNUMBEROFUSBSTORAGESgets number of attached usb storagesno parameter#*number of attached usb storages is … (numbers 0,1,2,…)
GETTOTALSPACEget total usb space (in MB)no parameter
or
usb index (numbers 1,2,….)
#*The total space is … MB
or
#*Invalid index (only for parametrized version)
GETFREESPACEget free usb space (in MB)no parameter
or
usb index (numbers 1,2,….)
#*The free space is … MB
or
#*Invalid index (only for parametrized version)
SAVEMODELINFOsaves model name and sw version
to a removable device
no parameter#*Model info is saved
OR
#*No Removable drive is connected
(If there is no device connected)
SETSCHEDULERenables/disables schedulerstring n (ON, OFF)
————————————
new command is available with

Ronesans_B2B r232185 –

Raphael V7.36.0.0:
“SETSCHEDULER N_X”
(N is scheduler number, X is “ON” or “OFF”)

#*The scheduler is set to …. (ON, OFF)
GETSCHEDULERget scheduler enabled/disabledno parameter
————————————
new command is available with

Ronesans_B2B r232185 –

Raphael V7.36.0.0:
“GETSCHEDULER N”

(N is scheduler number)

#*The scheduler is …. (ON, OFF)
SETSCHEDULEOPset scheduler parameters

string n ( on time_off time_source

in format: hh:mm_hh:mm_source )
————————————
new command is available with

Ronesans_B2B r232185 –

Raphael V7.36.0.0:
“SETSCHEDULEOP

number_enabled_ontime_

offenabled_offtime_days_source”
(SETSCHEDULEOP 4_1_

08:00_1_22:00_0111110_HDMI)
Available source names:
• LastSource
• USB
• DP
• OPS
• DVI
• HDMI
• YPbPr
• VGA/PC

#*Schedule parameters are … (set/not set).
GETSCHEDULEOPget scheduler parametersno parameter
————————————
new command is available with

Ronesans_B2B r232185 –

Raphael V7.36.0.0:
“GETSCHEDULEOP N”

(N is scheduler number)

#*Scheduler on/off time and source is: …… (hh:mm_hh:mm_source)
SETRCUset RCU Inhibit to on,offstring n ( ON, OFF )#*set RCU inhibit … (ON, OFF)
OR
#*Missing RCU Inhibit selection
OR
#*wrong string parameter for RCU Inhibit
GETRCUget RCU Inhibit valueno parameter#*RCU Inhibit is …. (ON, OFF)
OR
#*NACK
TSUtrigger sw updateno parameter#*Web Software Update search triggered !!!
SHOWSIGNAGEIDdisplay signage ID on screenno parameter#* Signage ID is 0 (1…99)
SETBROWSERMEMforce browser memory limit value in MBs

string n (any number between

100-700 for MB120DS,

0 for default limit)

#*Browser memory limit is set
GETBROWSERMEMgets browser memory limit value in MBsno parameter#*browser memory limit is: …..(numbers)
SETGPURASTERforce browser gpu raster state

string n ( ON, OFF , any

other string for default state)

#*GPU Raster state is set
GETGPURASTERgets browser gpu raster stateno parameter#*browser gpu raster is …. (ON, OFF)
SET4KBROWSERforce browser resolution as 4K

string n (ON, OFF (or any

other string) for default state)

#*Forced 4K browser is enabled
OR
#*Forced 4K browser is disabled
GET4KBROWSERgets browser resolution state as 4Kno parameter#*browser 4K is …. (ON, OFF)
AUTOSETSIGNAGEIDSets signage id automatically.
For usage the feature the AdvancedVideoWall profile item should be enable.
no parameter#*
OR
#*AdvancedVideoWall profile item is disabled.
C2CONNECTIONReturns the handshake result between G6F and C2 devicesno parameter#*FAILURE, wait to check C2 availability (process still not finished)
OR
#*FAILURE, C2 is not READY (handshake failed, C2 is not available)
OR
#*SUCCESS, C2 is READY (handshake is succeded)
UART_CHECKStarts the handshake process between G6F and C2
devices
no parameter#*C2 handshake process is started
GETTEMPERATUREMeasure ambient temperature using temperature sensorno parameter#*TEM=…
OR
#*Temperature sensor is not available
GETHUMIDITYMeasure relative humidity using humidity sensorno parameter#*HUM=…
OR
#*Humidity sensor is not available
SETVIDEOCROPCrop input video with given parameters and show full
screen.
Wideowall must be disabled or cell number must be zero
to activate this feature.
Set width or height as 0 to disable crop.
string (X-Y-W-H)#*set x position to X, set y position to Y, set
width to W, set height to H
GETVIDEOCROPGet crop parametersno parameter#*x position is X, y position is Y, width is W,
height is H
LENLED Bar PWM Enable/Disable of the given colorstr-int n (W, R, G, B) (0 – 1)#*SUCCESS #*FAILURE
LPELED Bar PWM Period value of the given colorstr-int n (W, R, G, B) (0 – 65535)#*SUCCESS #*FAILURE
LDCLED Bar PWM Division value of the given colorstr-int n (W, R, G, B) (0 – 65535)#*SUCCESS #*FAILURE
LDILED Bar PWM Division value of the given colorstr-int n (W, R, G, B) (0 – 65535)#*SUCCESS #*FAILURE
LBELED Bar Enable/Disable via GPIOint n (0, 1)#*SUCCESS
LCOLED Bar Color drive

string (red_green_blue_white)

(color level value as string)

#*FAILURE, lacking parameter! #*FAILURE, parameter exceeds the limit! #*FAILURE, no parameter after ‘_’ character! #*FAILURE, all colors are not processed #*SUCCESS
C2MSGSends message to UART2 (C2 connection)string#*SUCCESS, Message Send: %s
SETC2PROFILEThe profile file name of C2 is saved in Aurora side.

string (length_of_the_profile_

name/profile_name/END)

#*FAILURE, lacking parameter! #*FAILURE, parameter exceeds the limit! #*FAILURE, profile string is too long! #*FAILURE, profile string length is not matching! #*FAILURE, ‘END’ string could not be captured correctly! #*FAILURE, no parameter after ‘/’ character! #*FAILURE, all parameters are not processed #*SUCCESS
GETBOARDNAMESends the board name to C2 side

string (length_of_the_board_

name/board_name/END)

#*SUCCESS, Board Name: XXXXXXXXX
GETGYROSends the orientation mode to C2 side (The orientation information comes from gyro sensor to rotate android display automatically)no parameter#*SUCCESS, GyroSensorStatus: GYUG or GYRG or GYDG or GYLG
SETMODE_EMBEDDEDTOUCHSet the embedded touch mode string (external, display, android, ops)

#*Embedded touch mode is set to *****

or

#*Embedded touch mode is not set (invalid input)

GETMODE_EMBEDDEDTOUCHGet the embedded touch mode no parameter

#*Embedded touch mode is *****

or

#*Embedded touch mode is (invalid input)

SETMODE_WIFIBT Set the wifi&bt switch value string (auto, display, android)

#*Wifi & BT Switch Mode is set to *****

or

#*Wifi & BT Switch Mode is not set (invalid input)

GETMODE_WIFIBT Get the wifi&bt switch value no parameter

#*Wifi & BT Switch Mode is *****

or

#*Wifi & BT Switch Mode is (invalid input)

SETMODE_MICSet the DSP(Mic) and Front USB status valuestring (auto, display, android, ops)

#*Mic Mode is set to *****

or

#*Mic Mode is not set (invalid input)

GETMODE_MICGet the DSP(Mic) and Front USB status valueno parameter

#*Mic Mode is ****

or

#*Mic Mode is (invalid input)

SETAUTOLAUNCHSet the auto launch valuestring (cms, openbrowser, disabled, vsignlite (vsignlite only MB135VS))

#*Auto launch mode is set to *****

or

#*Auto launch mode is not set (invalid input)

GETAUTOLAUNCHGet the auto launch valueno parameter

#*Auto launch mode is ****

or

#*Auto launch mode is (invalid input)

SETBT
 string n (ON, OFF)

BT is disabled

or

To activate bluetooth reboot the display

Table 1: Signage settings commands